10/06/2022April Daniels
																	
							
							
								  OnGuard 7.5  Encryption for Controllers User Guide  does not contain steps or correct names for TLS certificates to install.  Procedure Steps    Configure TLS Encryption Using a Default Certificate Prerequisites    1. Establish unencrypted communic...							
						 
											
														
							
								10/06/2022April Daniels
																	
							
							
								 Symptom   LNL-1320 Series 3 board is not coming online, while the LNL-1320 Series 2 board connects instantly when swapped.   Resolution   Remove all terminations from downstream devices up to the access panel.   Applies To   All versions of OnGuard ...							
						 
											
														
							
								10/06/2022April Daniels
																	
							
							
								 Notice for users regarding powering readers from the LNL-X4420, LNL-X2220, and the Series 3 MR52. The Reader Power Select option on the LNL-X4420, LNL-X2220, and Series 3 boards has changed.  Procedure Steps   When 12 VDC is applied to power the boa...							
						 
											
														
							
								10/06/2022April Daniels
																	
							
							
								 How to collect an LNL-4420 crash dump       If problems occur when rebooting LNL-4420 panels or there are other instability issues with these panels, and you escalate the issue to Mercury, they may ask for a crash dump. This article addresses how to...							
						 
											
														
							
								10/06/2022April Daniels
																	
							
							
								 Product Name       LNL-3300-M5 and LNL-4420 Wireless Lock Compatibility     General Information     The LNL-3300-M5 does support the Assa Abloy Aperio and Schlage wireless lock solutions. The Aperio hubs or Schlage gateways need to be wired to port ...							
						 
											
														
							
								10/06/2022Content Creator
																	
							
							
								  Symptom:  Unable to access web configuration page for LNL-3300, LNL-2220 and LNL-2210      Cause:  Legacy panels use TLS 1.0 which is no longer supported by most browsers.      Note on Google Chrome:    TLS 1.0 and 1.1 were deprecated in Chrome 72 ...							
						 
											
														
							
								10/06/2022April Daniels
																	
							
							
								 Symptom  Alarms from EST3 panels are not shown in OnGuard for all double-byte languages (for example, Russian, Chinese, Japanese, Korean, Arabic, etc.). Alarm Monitoring shows junk characters in the alarms received from EST3 panels, instead of showi...							
						 
											
														
							
								10/06/2022April Daniels
																	
							
							
								 Question     How do I log out of the Guardall PX/QX/RX LCD Keypad?  Answer    To log out of the LCD Keypad, press the X key followed by the "confirm" or check mark key.  Applies To    Guardall PX/QX/RX Control Panels   Additional Information    None...							
						 
											
														
							
								10/06/2022April Daniels
																	
							
							
								 Symptom        A newly added access panel does not come online in Alarm Monitoring.  The panel and all its added child devices display a red X in the System Status Tree. The LenelError.Log displays the following error message:    TIME:      [08/24/2...