10/06/2022April Daniels
Problem Overview Double Video on Alarm with LDVR (OG-15506) Detailed Description For customers using LDVR (non-hybrid systems only), the setting in the ACS.INI file must be set to 0 on all client computers and channel pre-roll values need ...
10/06/2022April Daniels
Problem Overview Spservn.exe Service Stops or Closes Unexpectedly When More Than 20 TB of Storage is in Use (OG-19312) Detailed Description A maximum storage capacity of 20 TB is recommended for LDVR. Larger storage sizes may cause the spser...
10/06/2022April Daniels
Problem Overview Daylight Saving Time Should Be Disabled on goVision Recorders (OG-20353/OG-20547) Detailed Description Daylight Saving Time (DST) should be disabled on the goVision recorder. OnGuard should be used to control the time for th...
10/06/2022April Daniels
How to upgrade an LDVR GO! system Procedure Steps 1) Stop all LDVR and OnGuard services on the digital video recorder. 2) Start the installer ( setup.exe ) for the new LDVR firmware. 3) The setup utility will first uninstall the old LDVR fir...
10/06/2022April Daniels
How to identify and repair a corrupt LDVR Procedure Steps If an LDVR stops recording, but all services seem to be running correctly, check the lnlVideo.log file on the LDVR. This file is usually located in C:\Program Files\Lenel Systems\LDVR...
10/06/2022April Daniels
How to uninstall LDVR firmware Procedure Steps 1) In Control Panel > Add or Remove Programs , remove LDVR , where is the version of LDVR firmware. 2) Delete the following folders: - C:\Program Files\Common Files\Lenel - C:\Program Files\Len...
10/06/2022April Daniels
How to add or replace digital video capture cards Procedure Steps For detailed information, refer to the Digital Video Hardware User Guide. 1) Delete the recorder in System Administration. Note: Camera and device links will be lost when t...
10/06/2022April Daniels
How to obtain detailed information about the LDVR using SpDiag.exe Procedure Steps The information generated by the Spider Diagnostic application ( SpDiag.exe ) is often requested by Technical Support and useful for determining whether the fir...
10/06/2022April Daniels
Symptom If an LDVR is disconnected from an OnGuard system for an extended period of time, communication errors that have not been processed by the Communication Server may be generated and saved on the LDVR. When connected, the LDVR slowly rele...
10/06/2022April Daniels
Symptom The LDVR intermittently fails to record due to HyperThreading. Resolution To disable hyperthreading: 1) Restart the computer. You must perform the next step before the operating system boot begins. 2) Enter LDVR BIOS as described ...