System Administration

Intrusion Mask Group option does not appear in the Group Type drop-down

10/06/2022April Daniels
 Symptom In System Administration, the Intrusion Mask Group option does not appear  in the Group Type drop-down. Resolution Intrusion mask groups can only be added to LNL-2220 and LNL-3300 access panels. You must select one of these ty...

Cannot select network printers when configuring a Global I/O or scheduled task to print a report

10/06/2022April Daniels
Symptom Network printers cannot be selected when you configure Schedule Report as the action type to be executed by a Global I/O or from Scheduler. In System Administration, complete the following steps in order to reproduce the issue: 1) Fr...

An error occurs during automatic cropping of a cardholder image

10/06/2022April Daniels
Symptom When attempting to capture a photo for a cardholder, you may encounter the error message: "An error occurred while attempting to automatically crop the cardholder image. Failed to process image. The image dimensions are too small. A min...

''Invalid Badge'' at HID Edge reader, but cardholder name and badge number appear correctly in Alarm Monitoring

10/06/2022April Daniels
Symptom When a cardholder presents their badge to an HID Edge or EdgePlus reader, you may see an "Invalid Badge" event in Alarm Monitoring even though the displayed cardholder name and badge number are correct. Resolution The card format ass...

Readers connected to LNL-2220 reader ports appear offline in Alarm Monitoring

10/06/2022April Daniels
Symptom Readers connected to LNL-2220 reader ports appear offline in Alarm Monitoring, marked with a yellow X in the System Status Tree. Resolution Ensure that the Reader Type for the reader that is connected to the reader port of the LNL-22...

PIN codes do not work on Schlage SERIII-W Scramble Keypad reader

10/06/2022April Daniels
Symptom When using the Schlage SERIII-W Scramble Keypad reader, you may experience any or all of the following issues: - PIN codes do not work. - Access Granted events are not displayed in Alarm Monitoring. - Access denied even when a valid PIN ...

Cannot assign more than two (2) intrusion authority levels per badge

10/06/2022April Daniels
Symptom You are not able to assign more than two (2) intrusion authority levels to a badge. When two (2) intrusion authority levels are assigned to a badge and an attempt is made to assign a third intrusion authority level, the first level assi...

Third-party OPC Clients are not receiving events from OnGuard (as OPC Server)

10/06/2022April Daniels
Symptom Third-party OPC Clients do not receive events from OnGuard (as OPC Server). Resolution This problem occurs when the OnGuard license is missing the required DataConduIT client option (part number SWG-1140). To correct this problem:  ...

Badge layouts no longer present on one or more Regional Server Nodes

10/06/2022April Daniels
Symptom Badge layouts are no longer present on one or more Regional Server Nodes after the Replicator application is executed from a Master Server Node to a Regional Server Node. This occurs if the Download system records check box was selecte...

Unable to add an access level to a cardholder

10/06/2022April Daniels
Symptom In System Administration and ID CredentialCenter, on the Cardholders folder Access Level form, the [Modify] button is disabled, preventing the addition of access levels to a cardholder. Resolution This is normal behavior if a badge h...