Question
Answer
LNL-3300-M5
No | Description | LNL-1380-8RP | LNL-1320-2RP | LNL-1320-S2RP | LNL-1320-S3 | |
| Mode/State | SF2F | WIU-4 to Wiegand† | SF2F | SF2F | SF2F |
1 | Card and Pin – Normal State | Solid Blue | Solid Blue | Solid Blue | Solid Blue | Solid Blue |
2 | Card only – Normal State | Solid Blue | Solid Blue | Solid Blue | Solid Blue | Solid Blue |
3 | Pin or Card – Normal State | Solid Blue | Solid Blue | Solid Blue | Solid Blue | Solid Blue |
4 | Facility Code Only – Normal State | Solid Blue | Solid Blue | Solid Blue | Solid Blue | Solid Blue |
5 | Locked | Solid Blue | Solid Blue | Solid Blue | Solid Blue | Solid Blue |
6 | Unlocked | Solid Green | Solid Green | Solid Green | Solid Green | Solid Green |
7 | Access Granted | Yellow Flash to Solid Green | Solid Green | Yellow Flash to Solid Green | Yellow Flash to Solid Green | Yellow Flash to Solid Green |
8 | Access Denied | Solid Yellow for 1 sec | Green and Blue – Alternating for 3 sec | Solid Yellow for 1 sec | Solid Yellow for 1 sec | Solid Yellow for 1 sec |
9 | waiting for PIN◊ | ² Solid Yellow for 1 sec | ²Green and Blue – Alternating for 3 sec | ³ Solid Yellow for 3 sec | ³ Solid Yellow for 3 sec | ³ Solid Yellow for 3 sec |
² BD reader and T reader have same behavior
³ BD readers only
◊ Mercury Need to change firmware for LNL-1380-8RP, LNL-1320-2RP, LNL-1320-S2RP and LNL-1320-S3
†Wiegand T525SW,
BD reader-F/2F enabled (Dev36),
BD reader-not F/2F enabled
Applies To
Additional Information
- OnGuard: Version 7.4.457.69
- LNL-3300-M5: Firmware 1.256
- LNL-1380-8RP: Firmware 1.57.14
- LNL-1320-2RP: Firmware 1.57.15
- LNL-1320-S2RP: Firmware 1.57.15
- LNL-1320-S3: Firmware 3.20.4