General Information
When using a NetDVMS or RC-C recorder with an Axis Encoder, if the Axis Encoder is disconnected, Alarm Monitoring will indicate the lost connections to the corresponding cameras correctly. Approximately 2 minutes later, Alarm Monitoring will briefly (and incorrectly) identify those cameras as having been reconnected. Within a few seconds, the correct (disconnected) status will once again be reflected. This is a recorder limitation.
The sequence of alerts from the NetDVMS/RC-C recorder will typically follow this pattern for a given camera when the Axis Encoder is disconnected:
The sequence of alerts from the NetDVMS/RC-C recorder will typically follow this pattern for a given camera when the Axis Encoder is disconnected:
- [t0] Not Responding
- [t0 + 120s] Responding
- [t0 + 121s] Disabled
- [t0 + 122s] Enabled
- [t0 + 127s] Not Responding
Applies To
OnGuard (All versions)