How to wire a L1 4G reader for enrollment over RS-232 instead of USB
Last Modified on 10/06/2022 4:15 am EDT
How to wire a L1 4G reader for enrollment over RS-232 instead of USB
Procedure Steps
1. For RS-232 installations, a female DB9 connector should be used on the cable.
2. Connect RS232_TX (Violet wire - Pin 4 of 28) to the DB9 - Pin 2.
3. Connect RS232_RX (Violet/White wire - Pin 2 of 28) to the DB9 - Pin 3.
4. Connect Signal Ground (Black / Red wire - Pin 6 of 28) to the DB9 - Pin 5.Applies To
OnGuard (All versions)Additional Information