Procedure Steps

1) Exit the Alarm Monitoring or VideoViewer application.

2) Open the ACS.INI file in a text editor and add the following lines: 

[DigitalVideo]
CPUPauseLimit=50
CPUResumeLimit=40

Note: In the above example, Alarm Monitoring and VideoViewer will stop displaying video when the CPU usage reaches 50% and resumes playing when the CPU usage reaches 40%.  
 

Applies To

OnGuard (All versions)

Additional Information

This is changed on a per-computer basis.

The default limits are:
Pause: 90%
Resume: 70%

If the video window has a red border the video is paused. The video will resume when the CPU limit reaches the Resume Limit set in the ACS.INI file.